Although weighing transducers are accurate, these devices are prone to deterioration due to continuous use and may provide inaccurate measurement results. To ensure the normal operation of the load cell system, the weight indicator must be reset to zero when the system is unloaded.
Even if the load position changes (uneven load), the system should be able to indicate the same weight. If your weighing transducer system does not show these signs, it is time to recalibrate the load cell. There are several tests that can be used to check whether your load cell system is causing problems. These include mechanical inspection, zero balance test, bridge resistance test, and ground resistance test.
For scales, the first step in calibrating weighing transducers is to install the equipment in a stable environment. Then, use the calibration mode in your weighing transducer to adjust the settings. Usually, there is an option called "Span Calibration". Select this option to calibrate and use the test load on the load cell. Wait for the weighing transducer to be adjusted. Once adjusted, press Enter to complete the calibration process.